Test type and location
Check boxes for scheduled, new installation or special, then field office, building and location, and circuit designation.
GSA2543
Low Voltage Circuit Breaker Test Record (Less than 600 volts)
GSA Form 2543, Low Voltage Circuit Breaker Test Record (Less than 600 volts), is a one-page General Services Administration record. The footer reads GSA FORM 2543 (Rev. 1-70), and GSA hosts it in its forms library. GSA's page lists a current revision date of 01/1970 and no authority or regulation.
The form records one breaker test: whether it was scheduled, a new installation or special, the field office, building and location and circuit designation, the breaker's make, type, frame, trip device, coil rating and curve number, and the long time, short time and instantaneous range and setting. It then logs contact resistance, a megger reading and the trip units as found and as left, in amps and seconds, under AO, BO and CO.
The form ends with remarks and the analyst's name and date. It prints no instructions and does not spell out its abbreviations. You can fill it out free in your browser on this page and download the result without an account.

Check boxes for scheduled, new installation or special, then field office, building and location, and circuit designation.
Make, type, frame, trip device, coil rating and curve number.
Range and setting for long time, short time and INST., then contact resistance under AO, BO and CO, and a megger line.

Minimum pick up in amps, long time and short time in amps and seconds, and INST. in amps, each under AO, BO and CO.

The same rows and columns again, under the heading TRIP UNITS AS LEFT.
A remarks area, the analyst's name and the date.
Check scheduled, new installation or special.
Enter the field office, the building and location, and the circuit designation.
Enter the make, type, frame, trip device, coil rating and curve number, then the range and setting for long time, short time and INST.
Record contact resistance and the megger reading, then the trip units as found and as left in amps and seconds under AO, BO and CO.
Note any remarks, then enter the analyst's name and the date.
The form prints no instructions. These steps follow its blocks from top to bottom.
You get the real form, filled in a browser tab, with nothing standing between you and the finished PDF.
The form prints no address or routing. It names a field office at the top and an analyst at the foot.
The footer reads GSA FORM 2543 (Rev. 1-70). GSA's page lists a current revision date of 01/1970 and no authority or regulation.
No instructions, test limits, OMB number or privacy statement, and no explanation of AO, BO, CO or INST.
The ANALYST (Name) block and a DATE block at the foot of the form record who did the test and when. The form has no other signature block.
The FIELD OFFICE block names the office the record belongs to, above the building and location.
A SCHEDULED check box is the first of three test types at the top of the form.
Separate NEW INSTALLATION and SPECIAL check boxes sit beside SCHEDULED. The form says nothing more about when each applies.
The form names one role, the analyst. Its top blocks show where and why the test took place.
The agency’s own page for Form GSA2543.
The official blank form, to print or fill by hand.
No tool matches that search.
The footer reads GENERAL SERVICES ADMINISTRATION and GSA FORM 2543 (Rev. 1-70). GSA hosts it in its forms library, and its page lists no authority or regulation.
The title reads Low Voltage Circuit Breaker Test Record (Less than 600 volts).
The form has one person block, ANALYST (Name), with a date beside it. It does not say who the analyst works for beyond the field office named at the top.
The form has two trip unit tables with the same rows, one headed TRIP UNITS AS FOUND and one headed TRIP UNITS AS LEFT. It prints no further explanation.
No. It has blank fields for readings in amps and seconds but prints no limits, settings or instructions.